Emergency Lighting Systems

For over a decade we've bought light to safety.
Expert help is a call/click away.

844-394-8247

Quick Tips

OSHA Code of Federal Regulations
• Requires adequate and reliable illumination for all exits
• Requires proper maintenance to assure that exit lighting is in continuously proper operating condition
NFPA 70 - National Electric Code
• Requires specific illumination and performance of emergency and exit lights
• Provides functional standards for battery-powered emergency and exit lighting
NFPA 101 - Life Safety Code
• Requires a monthly inspection of all emergency and exit lighting systems
• Requires an annual test of all emergency and exit lighint systems
International Fire Code
• Requires proper illumination of means of egress
• Requires assurance that emergency and exit lighting systems will provide illumination for at least 60 minutes
NFPA 1997 5-9.3
Periodic Testing of Emergency Lighting Equipment
An annual test shall be conducted for a 1-1/2 hour duration. Equipment shall be fully functional for the duration of the test.
Standard Fire Prevention Code 1999
807.1.4 Exit Illumination and Signs A functional test shall be conducted on every required emergency lighting system at 30-day intervals for a minimum of 30-seconds.

Emergency Lights

Standard LED Emergency Light Series : ELLE

Standard LED Emergency Light Series : ELLE


White or Black Housing

Buy your ELLE series today at the low price of $16

Adjustable Optics LED Emergency Light Series : ELRTL

Adjustable Optics LED Emergency Light Series : ELRTL


Adjustable Optics LED Emergency Light Series : ELRTL

Buy your ELRTL series today at the low price of $18

Decorative Halogen or LED MR16 Emergency Light

Decorative Halogen or LED MR16 Emergency Light


Decorative Halogen or LED MR16 Emergency Light available in White or Black Housing

Buy your EL16 series today at the low price of $25

Decorative High-Capacity Emergency Light with 9-hour Runtime Series: ELMR50

Decorative High-Capacity Emergency Light with 9-hour Runtime Series: ELMR50


Decorative High-Capacity Emergency Light with 9-hour Runtime Series: ELMR50

Buy your ELMR50 series today at the low price of $90

Remote Capable MR-16 Emergency Light Series : ELR16HO

Remote Capable MR-16 Emergency Light Series : ELR16HO


White or Black Housing

Buy your ELR16HO series today at the low price of $24

Semi-Recessed MR-16 Emergency Light Series : ELMR16L

Semi-Recessed MR-16 Emergency Light Series : ELMR16L


Semi-Recessed MR-16 Emergency Light Series : ELMR16L

Buy your ELMR16L series today at the low price of $24

Remote Capable LED Emergency Light Series : ELRFH

Remote Capable LED Emergency Light Series : ELRFH


Remote Capable LED Emergency Light Series : ELRFH

Buy your ELRFH series today at the low price of $24

LED Low Profile Thermoplastic Emergency Light Series : ELEO

LED Low Profile Thermoplastic Emergency Light Series : ELEO


LED Low Profile Thermoplastic Emergency Light Series : ELEO

Buy your ELEO series today at the low price of $26

Fixed-Optics Incandescent Emergency Light Series : ELR2

Fixed-Optics Incandescent Emergency Light Series : ELR2


White or Black Housing

Buy your ELR2 series today at the low price of $30

Wet Location Semi-Recessed MR-16 Emergency Light Series  : ELMR16WP

Wet Location Semi-Recessed MR-16 Emergency Light Series : ELMR16WP


Clear housing design looks great

Buy your ELMR16WP series today at the low price of $48

Glare-Free PAR-Type Emergency Light Series : ELNYXR

Glare-Free PAR-Type Emergency Light Series : ELNYXR


Glare-Free PAR-Type Emergency Light Series : ELNYXR

Buy your ELNYXR series today at the low price of $60

Thermoplastic Emergency Light Series : ELEC

Thermoplastic Emergency Light Series : ELEC


Thermoplastic Emergency Light Series : ELEC

Buy your ELEC series today at the low price of $62

5-8.1.3* The floors of means of egress shall be illuminated at all points including angles and intersections of corridors and passageways, stairways, landings of stairs, and exit doors to values of not less than 1 footcandle (10 lx) measured at the floor. Exception: In assembly occupancies, the illumination of the floors of exit access shall be not less than 1/5 footcandle (2 lx) during periods of performances or projections involving directed light.

5-9.2.1*
 Emergency illumination shall be provided for a period of 1 1/2 hours in the event of failure of normal Lighting. Emergency Lighting facilities shall be arranged to provide initial illumination that is no less than an average of 1 footcandle (10 lx) and a minimum at any point of .1 footcandle (1 lx) measured along the path of egress at floor level. Illumination levels may decline to .6 footcandle (6 lx) average and a minimum at any point of .06 footcandle (.6 lx) at the end of the emergency Lighting time duration. A maximum to minimum illumination uniformity ratio of 40 to 1 shall not be exceeded.




Protecting Those Who Serve