Quick Tips

OSHA Code of Federal Regulations
• Requires adequate and reliable illumination for all exits
• Requires proper maintenance to assure that exit lighting is in continuously proper operating condition
NFPA 70 - National Electric Code
• Requires specific illumination and performance of emergency and exit lights
• Provides functional standards for battery-powered emergency and exit lighting
NFPA 101 - Life Safety Code
• Requires a monthly inspection of all emergency and exit lighting systems
• Requires an annual test of all emergency and exit lighint systems
International Fire Code
• Requires proper illumination of means of egress
• Requires assurance that emergency and exit lighting systems will provide illumination for at least 60 minutes
NFPA 1997 5-9.3
Periodic Testing of Emergency Lighting Equipment
An annual test shall be conducted for a 1-1/2 hour duration. Equipment shall be fully functional for the duration of the test.
Standard Fire Prevention Code 1999
807.1.4 Exit Illumination and Signs A functional test shall be conducted on every required emergency lighting system at 30-day intervals for a minimum of 30-seconds.

Emergency Lights

20 Gauge Steel Emergency Light Series : ELSL

20 Gauge Steel Emergency Light Series : ELSL


20 Gauge Steel Emergency Light Series : ELSL

Buy your ELSL series today at the low price of $125

Decorative Outdoor LED Emergency Light Series : ELBO

Decorative Outdoor LED Emergency Light Series : ELBO


Many Functions, Many Housing Colors

Buy your ELBO series today at the low price of $155

Incandescent Emergency Light Series : ELTB

Incandescent Emergency Light Series : ELTB


Incandescent Emergency Light Series : ELTB

Buy your ELTB series today at the low price of $215

High Impact Enclosure Power Unit Emergency Light Series : ELKS

High Impact Enclosure Power Unit Emergency Light Series : ELKS


High Impact Enclosure Power Unit Emergency Light Series : ELKS

Buy your ELKS series today at the low price of $258

Vandal-Resistant Housing Battery Unit Series : ELV18M

Vandal-Resistant Housing Battery Unit Series : ELV18M


Vandal-Resistant Housing Battery Unit Series : ELV18M

Buy your ELV18M series today at the low price of $285

Die-Cast Aluminum LED Emergency Light Series : ELUX

Die-Cast Aluminum LED Emergency Light Series : ELUX


Die-Cast Aluminum LED Emergency Light Series : ELUX

Buy your ELUX series today at the low price of $286

High Impact Thermoplastic Emergency Light Series : ELST

High Impact Thermoplastic Emergency Light Series : ELST


High Impact Thermoplastic Emergency Light Series : ELST

Buy your ELST series today at the low price of $355

High Impact Thermoplastic Emergency Light Series : ELDT

High Impact Thermoplastic Emergency Light Series : ELDT


High Impact Thermoplastic Emergency Light Series : ELDT

Buy your ELDT series today at the low price of $475

Industrial Architectural Emergency Light Series : ELIAEL

Industrial Architectural Emergency Light Series : ELIAEL


Industrial Architectural Emergency Light Series : ELIAEL

Buy your ELIAEL series today at the low price of $230

Decorative Industrial Emergency Light Series : ELIDE

Decorative Industrial Emergency Light Series : ELIDE


Decorative Industrial Emergency Light Series : ELIDE

Buy your ELIDE series today at the low price of $256

Industrial High Capacity Emergency Light Series : ELIHC

Industrial High Capacity Emergency Light Series : ELIHC


Industrial High Capacity Emergency Light Series : ELIHC

Buy your ELIHC series today at the low price of $355

Industrial Wet Location Emergency Light Series : ELIWL

Industrial Wet Location Emergency Light Series : ELIWL


Industrial Wet Location Emergency Light Series : ELIWL

Buy your ELIWL series today at the low price of $335

5-8.1.3* The floors of means of egress shall be illuminated at all points including angles and intersections of corridors and passageways, stairways, landings of stairs, and exit doors to values of not less than 1 footcandle (10 lx) measured at the floor. Exception: In assembly occupancies, the illumination of the floors of exit access shall be not less than 1/5 footcandle (2 lx) during periods of performances or projections involving directed light.

5-9.2.1*
 Emergency illumination shall be provided for a period of 1 1/2 hours in the event of failure of normal Lighting. Emergency Lighting facilities shall be arranged to provide initial illumination that is no less than an average of 1 footcandle (10 lx) and a minimum at any point of .1 footcandle (1 lx) measured along the path of egress at floor level. Illumination levels may decline to .6 footcandle (6 lx) average and a minimum at any point of .06 footcandle (.6 lx) at the end of the emergency Lighting time duration. A maximum to minimum illumination uniformity ratio of 40 to 1 shall not be exceeded.