Quick Tips

OSHA Code of Federal Regulations
• Requires adequate and reliable illumination for all exits
• Requires proper maintenance to assure that exit lighting is in continuously proper operating condition
NFPA 70 - National Electric Code
• Requires specific illumination and performance of emergency and exit lights
• Provides functional standards for battery-powered emergency and exit lighting
NFPA 101 - Life Safety Code
• Requires a monthly inspection of all emergency and exit lighting systems
• Requires an annual test of all emergency and exit lighint systems
International Fire Code
• Requires proper illumination of means of egress
• Requires assurance that emergency and exit lighting systems will provide illumination for at least 60 minutes
NFPA 1997 5-9.3
Periodic Testing of Emergency Lighting Equipment
An annual test shall be conducted for a 1-1/2 hour duration. Equipment shall be fully functional for the duration of the test.
Standard Fire Prevention Code 1999
807.1.4 Exit Illumination and Signs A functional test shall be conducted on every required emergency lighting system at 30-day intervals for a minimum of 30-seconds.

Emergency Lights

Steel Emergency Light Series : ELNY18

Steel Emergency Light Series : ELNY18


Steel Emergency Light Series : ELNY18

Buy your ELNY18 series today at the low price of $68

Chicago Approved Steel LED Emergency Light Series :ELCALR

Chicago Approved Steel LED Emergency Light Series :ELCALR


Chicago Approved Steel LED Emergency Light Series :ELCALR

Buy your ELCALR series today at the low price of $70

Adjustable Recessed Emergency Down-light Series : EMRL

Adjustable Recessed Emergency Down-light Series : EMRL


EMRL

Buy your EMRL series today at the low price of $71

Halogen Emergency Light Series : ELCA

Halogen Emergency Light Series : ELCA


Halogen Emergency Light Series : ELCA

Buy your ELCA series today at the low price of $72

Wet Location Remote Capable LED Emergency Light Series : ELTX

Wet Location Remote Capable LED Emergency Light Series : ELTX


Wet Location Remote Capable LED Emergency Light Series : ELTX

Buy your ELTX series today at the low price of $80

Incandescent Emergency Light Series : ELR7

Incandescent Emergency Light Series : ELR7


Incandescent Emergency Light Series : ELR7

Buy your ELR7 series today at the low price of $89

Fully Recess Emergency Light Series : ELSE

Fully Recess Emergency Light Series : ELSE


Fully Recess Emergency Light Series : ELSE

Buy your ELSE series today at the low price of $89

Wet-Location Incandescent Emergency Light Series : ELTFX2

Wet-Location Incandescent Emergency Light Series : ELTFX2


Wet-Location Incandescent Emergency Light Series : ELTFX2

Buy your ELTFX2 series today at the low price of $93

Remote Capable Incandescent Emergency Light Series : ELXR

Remote Capable Incandescent Emergency Light Series : ELXR


White or Black Housing

Buy your ELXR series today at the low price of $94

6 and 12 Volt Steel Enclosure Emergency Light Series : EL89

6 and 12 Volt Steel Enclosure Emergency Light Series : EL89


6 and 12 Volt Steel Enclosure Emergency Light Series : EL89

Buy your EL89 series today at the low price of $96

Steel  Emergency Light Series : ELSM

Steel Emergency Light Series : ELSM


Steel Emergency Light Series : ELSM

Buy your ELSM series today at the low price of $105

Steel Housing LED Emergency Light Series : ELSDXLR627

Steel Housing LED Emergency Light Series : ELSDXLR627


Steel Housing LED Emergency Light Series : ELSDXLR627

Buy your ELSDXLR627 series today at the low price of $107

5-8.1.3* The floors of means of egress shall be illuminated at all points including angles and intersections of corridors and passageways, stairways, landings of stairs, and exit doors to values of not less than 1 footcandle (10 lx) measured at the floor. Exception: In assembly occupancies, the illumination of the floors of exit access shall be not less than 1/5 footcandle (2 lx) during periods of performances or projections involving directed light.

5-9.2.1*
 Emergency illumination shall be provided for a period of 1 1/2 hours in the event of failure of normal Lighting. Emergency Lighting facilities shall be arranged to provide initial illumination that is no less than an average of 1 footcandle (10 lx) and a minimum at any point of .1 footcandle (1 lx) measured along the path of egress at floor level. Illumination levels may decline to .6 footcandle (6 lx) average and a minimum at any point of .06 footcandle (.6 lx) at the end of the emergency Lighting time duration. A maximum to minimum illumination uniformity ratio of 40 to 1 shall not be exceeded.




Protecting Those Who Serve